Part Number: ETI0001-1486
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| AC OUTPUT | |
| Output voltage: | 120 vac true sinewave standard |
| Output rating: UPS |
2000
va standard in 4U chassis x 18.5" deep 0.65-0.75 pf standard |
| Non-linear load capacity: | Up to 100% non-linear load capability w/o derating |
| Output voltage regulation: UPS |
± 3.0%
static regulation of nominal ± 4.0% dynamic (0 to 50% load step) |
| Overload surge capacity: | 110% for 10 minutes; 125% for 30 seconds |
| Harmonic distortion: | Less than 5.0% into 100% non-linear load |
| Output frequency: UPS |
60
Hz ± 2.5% synchronized to utility 60 Hz ± 1.0% w/ utility not available |
| Operational status |
AC Input status,
UPS operational, UPS alarm, Battery level, Low battery, Load level,
Overload LEDs, Elapsed time hour meter Alarm contacts for Loss of AC and Low Battery +90 dB audible alarm with audible on/off switch |
| AC INPUT | |
| Input voltage selection: | Nominal 115 vac, optionally autoranging input of 85-270 vac |
| Input voltage tolerance: UPS | 85-135 vac @ full load without using battery, to 70 vac @ 75% load |
| Input frequency: | From 46 hz to 70 hz standard, optional to 440 hz |
| Input power factor: | Better than 99% typically |
| Input/output isolation: | 2000 va, up to 120 dB common mode, <1.0 ma leakage |
| Input transient suppression: | Complies with IEEE 587, UL 1449 and Mil Std 1399 |
| Input control/protection: |
Guarded
2 pole 100 G shock rated circuit breaker (CB1) plus UPS input fuse (F2) Optional cold start switch available to turn on w/o ac present |
| Input power connection: | MS 3102A-22-2P, 3 pin, threaded locking |
| INTERNAL BATTERY | |
| Internal battery type: |
Maintenance
free immobilized electrolyte, Flame retardant materials (Oxygen Index 28+) |
| Internal battery life: | Rated for continuous service life of 5 years |
| Internal DC protection: | Panel mounted fuse standard, breaker optional |
| Internal battery time: |
15
minutes @ 1300 watts (2000 VA @ 0.65 pf, typical full load for
computers), 10 minutes @ 1500 watts load (maximum wattage), 35 minutes @ 50% load |
| Internal battery recharge: | Recharged to nominal in 8 hours |
| Internal battery replacement: | Drawout/plug-in module from front of unit |
| DISTRIBUTION PANEL | |
| Output circuits: | Six controlled outputs via solidstate relays |
| Output control: |
Local/remote
control panel w/individual load switches Thermal and remote interlock ON/OFF control |
| Output receptacles: | MS3102A16-10S threaded locking, various options |
| Operational status |
Low Battery,
On Battery, Warm temperature, Hot temperature, Battleshort and
individual Load On LEDs Alarm Reset pushbutton |
| MECHANICAL | |
| Dimensions ( H x D x W ): | 7.0 (4U) x 18.5 x 19.0 in (178 x 470 x 483 mm) |
| Rack Slide Mount Patterns: | Jonathan, General Devices patterns standard, others optional |
| Alternate Mounting Options: | Table, Wall, Floor, Portable, Horizontal/Vertical |
|
Unit weight:
Total UPS w/o Battery Module Drawout Battery Module |
169
lb. ( 77 kg) with lift handles front and rear 105 lb. ( 48 kg) with lift handles front and rear 64 lb. ( 29 kg) with lift handles rear |
| Audible noise: | Less than 47 dB @ 5.0 ft., ANSI "A" scale |
| Cooling type: | High capacity, positive pressure, forced air |
| Cooling air direction: | Front intake, exhaust to rear |
| Air intake filter: | Washable metal filter media, others optional |
| ENVIRONMENTAL | |
| Storage temperature: | -40° to 158° F ambient (-40° to 70° C) |
| Operating temperature: | 32° to 122° F ambient ( 0° to 50° C), lower/ higher optional |
| Operating humidity: | 0 to 95% relative humidity (non-condensing) |
| Storage elevation: | Up to 40,000 ft (12,192 m), higher optional |
| Operating elevation: | Up to 10,000 ft (3,048 m), higher optional |
| STANDARDS | |
| United States: |
Meets
UL-1778 standard for UPS equipment, MIL STDs 167-1, 454, 810D, 901D Grade A, 1399, Sec 300A & 2000 |
| Canada: | CSA C22.2 No. 107 UPS safety requirements |
| EMI Protection: | EMI/RFI FCC Part 15, Class A; EN55022; MIL STD 461 |
| OPTIONAL ACCESSORIES | |
| Autoranging International Input, Cold Start, Alternate I/O Configurations, Dual Source Input, Battery Expansion, Batteryless Operation, Battery Charger/Conditioner, Power Distribution Units, Software Interface, Asynchronous serial COM port, 10BaseT Ethernet SNMP/HTTP port, Transport Cases, Slides and Mounting Kits | |